5. Error Msg: External component has thrown an exception

Please check if the sensor is connected correctly to the connector. Note that the blue wire is the GND.

If you have the possibility to try other sensor and board please do it.

Please verify if the cables are broken loose from the connector. If so, the simplest way to solve this is to solder it yourself on your side. Please take a look on the following image explaining the connections. Please also note that the wires order is from GND then Data+, Data- and VDD.

6 pins:

 

4 pins:

 

Flex PCB connector, 6 pins:

 

Please run the board tester application, on Awaiba Viewer\application\debug, to see if the sensor is receiving data correctly.

 