Cmosis support

HomeORIONOrion SensorEnd of Range / ADC Gain Configuration

1.3. End of Range / ADC Gain Configuration

EORReg – End of Range Register Address: 0x06 setting has a linear relation with AGReg – Analogue Gain Register Address: 0x04 to get the 1V swing.  So for the each ADC resolution you have different Gains with master Clock 50 MHz :

Resolution Frame Rate ADC time EORReg Value(Hex) AGReg Value(Hex)
13 Bits 20 KHz 40 us FF CF
12 Bits 40 KHz 22 us 7F 9F
11 Bits 70 KHz 11 us 3F 40

 

 

 

 